Project planning notes
▶ The A10VSO axial piston variable pump is designed
to be used in open circuit.
▶ The project planning, installation and commissioning
of the axial piston unit requires the involvement of
qualified skilled personnel.
▶ Before using the axial piston unit, please read the corre-
sponding instruction manual completely and thoroughly.
If necessary, this can be requested from Bosch Rexroth.
▶ Before finalizing your design, please request a binding
installation drawing.
▶ Pressure controllers are not protection against overpres-
sure. A pressure relief valve is to be provided for the
hydraulic system.
▶ Working ports:
– The ports and fastening threads are designed for the
specified maximum pressure. The machine or system
manufacturer must ensure that the connecting ele-
ments and lines correspond to the specified application
conditions (pressure, flow, hydraulic fluid, temperature)
with the necessary safety factors.
▶ The specified data and notes contained herein must
be observed.
– The working ports and function ports are only
intended to accommodate hydraulic lines.
▶ Depending on the operating conditions of the axial
piston unit (working pressure, fluid temperature),
the characteristic curve may shift.
Safety instructions
▶ Preservation: Our axial piston units are supplied as
standard with preservative protection for a maximum of
12 months. If longer preservative protection is required
(maximum 24 months), please specify this in plain text
when placing your order. The preservation periods
apply under optimal storage conditions, details of
which can be found in the data sheet 90312 or in the
instruction manual.
▶ Not all versions of the product are approved for use
in a safety function according to ISO 13849. Please
consult the responsible contact person at Bosch
Rexroth if you require reliability parameters (e.g. MTTFd)
for functional safety.
▶ During and shortly after operation, there is a risk of
getting burnt on the axial piston unit and especially on
the solenoids. Take the appropriate safety measures
(e.g. by wearing protective clothing).
▶ Moving parts in control equipment (e.g. valve spools)
can, under certain circumstances, get stuck in position
as a result of contamination (e.g. impure hydraulic fluid,
abrasion, or residual dirt from components). As a result,
the hydraulic fluid flow and the build-up of torque in the
axial piston unit can no longer respond correctly to the
operator's specifications. Even the use of various filter
elements (external or internal flow filtration) will not
rule out a fault but merely reduce the risk. The machine/
system manufacturer must test whether remedial mea-
sures are needed on the machine for the application
concerned in order to bring the driven consumer into
a safe position (e.g. safe stop) and ensure any measures
are properly implemented.
▶ Depending on the type of control used, electromagnetic
effects can be produced when using solenoids. When a
direct current is applied, solenoids do not cause electro-
magnetic interference nor is their operation impaired by
electromagnetic interference.
Other behavior can result when a modulated direct
current (e.g. PWM signal) is applied. Potential electro-
magnetic interference for persons (e.g. persons with
a pacemaker) and other components must be tested
by the machine manufacturer.
.We not only provide high quality machinery and accessories for sale on the market, we also care about customers' profits and the
impact of machinery on the environment.If you want to know more details, please contact us immediately!